Assessment of Organ Dose and Effective Dose from Head Computed Tomography in Northwestern Nigeria

Authors

DOI:

https://doi.org/10.56919/usci.1222.013

Keywords:

Computed tomography, Effective dose, Dose length product, Computed tomography dose index.

Abstract

 

The amount of radiation dose received by patient undergoing Head computed tomography examination in General Amadi rimi orthopedics and specialist hospital, Katsina has been estimated. Computed tomography dose output was used to determine the effective dose and organ dose of non-contrast to the head region of 30 patients. The tube potential ranged from 127 kVp to 130 kVp, while the mAs ranged from 130 mAs to 140. The aims of this study are, first, to assess the mean effective doses received by patients undergoing Head CT examinations and compare them with other studies. Mean values of CTDIvol. was (43.1mGy), the mean DLP values was (1206 mGy.cm), the mean effective dose (HEDLP) value was (2.4 mSv). The result was compared with the European Union reference dose level and other published factor. HEDLP was slightly higher than the values reported from the literature for the united nation and European union report by 0.4 factor. It was concluded that patient organ doses could be substantially minimized, optimized and justified. The high variation in the doses in this study may be due to differences in imaging protocols such as large range of mAs and scan length and also algorithms of the scanner.

 

 

References

Abdulkadir, M.K., Schandorf, C. and Hasford, F. (2016) Determination of Computed Tomography Diagnostic Reference Levels of North-Central Nigeria. The Pacific Journal of Science and Technology, 17, 341-349.

Aldrich JE, Bilawich AM, Mayo JR. (2006) Radiation doses to patients receiving Computed Tomography examinations in British Columbia.Can Assoc Radiol journal, 57:79–8

Adejoh, T., Christian, N.C., Nkubil, F.B. and Dlama, J.Z. (2015) Effective Dose Levels from Computed Tomography of the Head during Contrast Studies in Nigeria. Health, 7, 915-919.

Berrington de Gonzalez, A. and Darby, S. (2004) Risk of Cancer from Diagnostic X-Rays: Estimates for the UK and 14 Other Countries. Lancet , 363, 345-351. https://doi.org/10.1016/S0140-6736(04)15433-0

Brown RA, Nelson JA.( 2012). Invention of the N localizer for stereotactic neurosurgery and its use in the Brown-Roberts-Wells stereotactic frame. Journal on Neurosurgery. 70 (Supplement 2):173–176

Dehn, T.G. (2007) Ionizing Radiation Exposure from Radiologic Imaging: The Issue of What We Can Do. https://hmsa.com/portal/provider/Radiation_Safety_Provider_Edu_4pgs.pdf

Desouky O., Nan Ding N., Zhou G (2015) ,Targeted and non-targeted effects of ionizing Galloway RL Jr . Introduction and historical perspectives on image-guided surgery. In Golby, AJ (ed.). Image Guided Neurosurgery. Amsterdam: Elsevier.2015; 34 -38

George,T,Rayan Babu,KN. And Thomas,P.T(2006)Reliability of Ultrasonography in the Diagnosis of Acute Appendicitis.International surgery Journal,3,59-61 https://doi.org/10.18203/2349-2902.isj20151509

Inkoon S.I, T.O Ntiri,J.Togobo,G.Emi-.Gyekye and A.Oddoye (2012).Retrospective Radiation Audit from Ghana’s first 64 Multi –slice Computed tomography.Radiation protection Institute,Ghana Atomic Energy Commission,P.O Box LG 80 Lagon Accra

Ghana ICRP (1990), The 1990 Recommendations of the International Commission on Radiological Protection. ICRP publication 60 Ann ICRP 1991, 21,(1-3)

International Commission on Radiological Protection (ICRP) Publication (2007) The 2007 Recommendations of the International Commission on Radiological Protection. Annals of the ICRP, 37, 1-332.

International Commission on Radiological Protection (ICRP) Publication (2007) Managing Patient Dose in Multi-Detector Computed Tomography (MDCT). Annals of the ICRP, 37, 1-63.

ICRP (2007) Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Exeter: Elisevier; 2007. Available at: http://journals.sagepub.com/doi/pdf/10.1177/ANIB 37 2-4.Accessed Jul 13, 2018 .

ICRP (2007) The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103 Ann ICRP, 37, 2-4..

Brown RA, Nelson JA. (2012) Invention of the N localizer for stereotactic neurosurgery and its Use in the Brown-Roberts-Wells stereotactic frame. Journal on Neurosurgery, 70 (Supplement 2):173–176

European Commission on radiation protection No.180. Medical radiation exposure of the European Population. Luxemburg: Publications Office of the European Union; 2014. Available at: https://ec.europa.eu/energy/sites/ener/files/documents/RP180.pdf. Accessed Jul 13, 2018.

Ekpo, E., Adejoh, T., Akwo, J.D., Emeka, O. C.,Modu, A., Abba, M., Adesina K., Omiyi, D. and Chiegwu. (2018) Diagnostic Reference Levels for Common ComputedTomography Examinations: Results from the First Nigerian Nationwide Dose Survey. Journal of Radiological Protection. 38:525–535. https://doi.org/10.1088/1361- 6498

Galloway RL Jr . Introduction and historical perspectives on image-guided surgery. In Golby, AJ (ed.). Image Guided Neurosurgery. Amsterdam: Elsevier.2015; 34 -38

Khan FR, Henderson JM (2013). Deep Brain stimulation surgical techniques. In Lozano, AM; Hallet, M (eds.). Brain stimulation: Handbook of clinical neurology. 116. Amsterdam: Elsevier. 28–30.

Mary-ann Etim Ekpo,Rachel Ibhade Obed,Akintayo,Damel Omojola(2018). south cli.1st Euras 2018;29 (2):125-131

Miglioretti, D. L., Johnson E., Williams A. Greenlee R. T., Weinmann S., Heather Spencer Feigelson H. S., Roblin D., Flynn M. J., Vanneman N. and Bindman R. S., “The Use of Computed Tomography in Pediatrics and the Associated Radiation Exposure and Estimated Cancer Risk”, Journal of the American Medical Association, . 167; 8, 700-707, 2013

Rehani, M.M. and Berry, M. (2000) Radiation Doses in Computed Tomography. BMJ , 320, 593-594. https://doi.org/10.1136/bmj.320.7235.593

National Council on Radiation Protection and Measurements (2009) Ionizing Radiation Exposure of the United States. National Council on Radiation Protection Report No. 160, National Council on Radiation Protection and Measurement, Bethesda, MD.

Khan FR, Henderson JM . Deep Brain stimulation surgical techniques. In Lozano, AM; Hallet, M (eds.). (2013).Brain stimulation: Handbook of clinical neurology.2013; 116.Amsterdam: Elsevier. P. 28–30.

Mary-ann Etim Ekpo,Rachel Ibhade Obed,Akintayo,Damel Omojola.(2018). south cli.1st Euras, 29(2):125-131

Inkoon, S.I, T.O Ntiri, J. Togobo, G.Emi-Reynolds,P.K.Gyekye and A.Oddoye.Retrospective Radiation Audit from Ghana’s first 64 Multi –slice Computed tomography.Radiation protection Institute,Ghana Atomic Energy Commission,P.O Box LG 80 Lagon Accra Ghana

Shrimpton P.C, Hillier M.C, Lewis M.A, Dunn M. Doses from Computed Tomography (CT) Examinations in the UK-2003 Review, National Radiological Protection Board, NRPB- W67,Chilton Didcot, Oxon OX11 ORQ, ISBN 0 85951 556 7, 2005

Sulemana H,Inkoon S, Sosu Kwabla E Schandorf C .(2020)Estimation of Absobed dose and Effective Dose in Organ through Computed Tomography Examination Using Automatic Exposure Control And Fixed Tube Current Technique:A Phanton Case Study.Iranian Journal of Medical physics. 17:58-65

Tse VCK., Kalani MYS, Adler JR.m (2015) Techniques of stereotactic localization. In China, LS; Regine, WF (eds.). Principles and Practice of Stereotactic Radiosurgery. New York: Springer. 28-29.

Tsapaki Virginia, John E. Aldrich, Raju Sharma, Maria Anna Staniszewska, Anchali Krisanachinda,Madan Rehani, Alan Hufton, Chariklia Triantopoulou, Petros N. Maniatis, John Papailiou, Mathias Prokop(2006) Dose reduction in CT while maintaining diagnostic confidence: Diagnostic reference levels at routine head, chest, and abdominal CT – IAEA Coordinated Research Project. Radiology , 240- 8

(UNSCEAR), (2010). United Nations Scientific Committee on the Effects of Atomic Radiation Fifty-seventh session, includes Scientific Report: summary of low-dose radiation effects on health. Vienna: United Nations; 2011. [Crossref] 2010

(UNSCEAR), (2013). United Nations Scientific Committee on the Effects of Atomic Radiation. Report to the General Assembly, with scientific annexes. Vol. I,II.

United Nations Scientific Committee on the effects of Atomic Radiation (UNSCEAR), 2008.

Downloads

Published

2022-12-30

How to Cite

Jamaladdeen, K., Bashir Gide Muhammad, & Ahmed Rufai Usman. (2022). Assessment of Organ Dose and Effective Dose from Head Computed Tomography in Northwestern Nigeria . UMYU Scientifica, 1(2), 103–108. https://doi.org/10.56919/usci.1222.013